50000kVA 132kV 3-phase 2-winding Power Transformer with OLTC

Payment Type: L/C,T/T
Incoterm: FOB,CFR,CIF
Min. Order: 1 Set/Sets
Delivery Time: 60-90 Days

Basic Info

Model No.: 50000kVA 132kV

Application: Power

Phase: Three

Coil: Core-type Transformer

Cooling Method: Oil-immersed Type Transformer

Certification: ISO9001, ISO9001-2000

Usage: Power Transformer

Frequency Characteristics: Power Frequency

Additional Info

Packaging: Seaworthy Packing

Productivity: 300 sets/year

Brand: QRE- QIANCHAO

Transportation: Ocean

Place of Origin: China

Supply Ability: High

Certificate: ISO

HS Code: 85042311

Port: China Sea Port

Product Description


Part I: Product Overview for 50000kVA 132kV Power Transformer with OLTC

50000kVA 132kV high quality oil immersed power transformer has optimized design using advanced technologies, in order to offer low noise, low partial discharge, high short circuit withstand capability. Advanced design software are used for electromagnetic calculation and design of transformer, while 3-D, 2-D CAD software for structural design ensure sufficient safety margin during short circuit period. This is based on in-depth theoretical and experimental studies on magnetic, thermal, mechanical strength and short circuit strength. To ensure reliability of the transformer, the insulation is decided based on calculation on main and vertical insulation. The accurate calculation of the electric field distribution in inner coils will ensure voltage gradient and at coil end it will ensure lower partial discharge.

Part II: Product Features

1.   Potential distribution is effectively improved by application of software to calculate the impact and gradient potential distribution. The potential calculation is also done between various parts of the coil including between the coil and coil and earthing.

 1

2.   Low loss: Magnetic flux leakage calculation and corresponding measures to effectively reduce the stray loss, and in the meantime effectively prevent local overheating and lower temperature rise of winding hot spots. The electromagnetic optimizing design software is applied to optimize the core and winding design.

2 

3.   High resistance to short-circuit capacity: Apply transformer resistance to short-circuit capacity accounting software to design HV winding and LV winding. HV winding will be designed as central outlet, up and down parallel connection with axial oil path; the regulating winding will be designed as central outlet in the middle of HV winding with up and down parallel connection to improve transformer short-circuit resistance.

3 

4.   Low partial discharge, extend transformer service life.

(1) Analyze calculation of electric field to improve the electric field concentrated region.

(2) The way of vacuum oil filling will effectively prevent the formation of air bubbles inside the transformer and insulation parts to reduce partial discharge.

4 

5.   Low noise: Lower the noise level by choosing high quality steel core material; right flux density and the self-vibration frequency of the core; application of high resistance to short-circuit of the body structure; and improving the connection method of tank and active part.

6.   Low temperature rise: Apply reasonable oil flow distribution structure by calculation of oil flow distribution; reduce the winding hot spot temperature rise and the average temperature rise in order to increase overload capacity of each part, extend the life of transformer.


Part III: Product Main Parameter

Capacity

(kV*A)

Model

Vector Group

No-load Loss

(kW)

Load Loss

(kW)

No Load Current (%)

Short-circuit Impedance (%)

Weight(kg)

Dimensions

Gauge (mm)

(T)

Oil

Total

LxWxH (mm)

50000

SZ11-50000/132

YNd11

38.2

194.0

0.46

12-18

19500

75900

5450x6860x5500

2040


 
Part IV: Outline Drawing

 

Outline Drawing





Power Transformer> 132kV Power Transformer> 31500kVA 132kV 3-phase 2-winding Power Transformer with OLTC
Dry Type Transformer> 33kV Dry Type Transformer> 2500kVA 33kV Dry-type Distribution Transformer
Power Transformer> 132kV Power Transformer> 40000kVA 132kV 3-phase 2-winding Power Transformer with OLTC
Dry Type Transformer> 11kV Dry Type Transformer> 30kVA 11kV Dry-type Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 30kVA 15kV Oil Immersed Distribution Transformer
Dry Type Transformer> 33kV Dry Type Transformer> 100kVA 33kV Dry-type Distribution Transformer
Dry Type Transformer> 33kV Dry Type Transformer> 250kVA 33kV Dry-type Distribution Transformer
Power Transformer> 33kV Power Transformer> 2000kVA 33kV 3-phase 2-winding Power Transformer with OLTC
Distribution Transformer> 15KV Distribution Transformer> 50kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 63kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 80kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 100kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 125kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 160kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 200kVA 15kV Oil Immersed Distribution Transformer
Distribution Transformer> 15KV Distribution Transformer> 250kVA 15kV Oil Immersed Distribution Transformer